More than 30 years experience in biosensors

1.      K. Cammann: Bio-Sensors Based on lon-Selective Electrodes”, Fresenius Z Anal Chem 287,1 -9 (1977)  creation of the term “Biosensor”

2.      K. Cammann, F. Honold: „Potentiell implantierbarer Glucose-Sensor“, Chem. Rundschau 20.6.1984

3.      K. Cammann, F. Honold: “Glucose Sensor Based on ISFETs”, Proc. 2nd Int. Meeting on Chemical Sensors, Bordeaux, pp. 554-56 (1986)

4.      K. Cammann, Th. Weiss: “An Amperometric Glucose Sensor With Combined Enzyme Layers”, in: Biosensors International Workshop 1987, GBF Monographs Vol. 10, pp. 267, VCH Verlagsgesellschaft, Weinheim (1987)

5.      K. Cammann, C. Oliveri: “Enzymatic Analysis of Trace Amounts of Zinc and Mercury”, in: Biosensors International Workshop 1987, GBF Monographs Vol. 10, pp. 281, VCH Verlagsgesellschaft, Weinheim (1987)

6.      K. Cammann, F. Honold: “Potentometric Glucose Sensor”, in: Biosensors International Workshop 1987, GBF Monographs Vol. 10, pp. 285, VCH Verlagsgesellschaft, Weinheim (1987)

7.      W Kerner, H. Zier, G. Steinbach, J. Brückel, E.F. Pfeiffer Th. Weiss, K. Cammann, H. Planck: “A Potentially Implantable Enzyme Electrode for Amperometric Measurement of Glucose”, Horm Metab Res, Suppl Ser (Implantable Glucose Sens) 20, 8 (1988)

8.      Th. Weiss, K. Cammann: “An Amperometric Glucose Sensor with Combined Enzyme Layers”, Horm Metab Res, Suppl Ser (Implantable Glucose Sens) 20, 23-25 (1988)

9.      F. Honold, K. Cammann: Potentiometrie Glucose Sensors”, Horm Metab Res, Suppl Ser (Implantable Glucose Sens) 20,47 (1988)

10.   K. Cammann, K. Jahn, A. Rohen, Th. Weiss, H. Wilken, B. Winter: “Comparison of Electrochemical with Optical Biosensors”, in: R.D. Schmid, F. Scheller (eds.): Biosensors – Application in Medicine, Environmental Protection and Process Control, GBF Monographs 13: pp. 201-11, VCH Verlagsgesellschaft Weinheim (1989)

11.   B. Winter, K. Cammann: “HCHO-Analysis by Electrochemical Biosensor-FIA”, Fresenius Z Anal Chem 334,720 (1989)

12.   A. Rohen, K. Cammann: Enzymatic optical Determination of Lactate by Reversible Reduction of Methylene Blue”, Fresenius Z Anal Chem 334, 720 (1989)

13.   A. Rohen, J. Krause, K. Cammann: „Enzymatic Photometric determination of lactate by reversible reduction of methylene blue”, Fresenius Z Anal Chem 338, 168-71 (1990)

14.   K. Cammann, U. Lemke, A. Rohen, J. Sander, H. Wilken, B. Winter: „Chemo- und Biosensoren – Grundlagen und Anwendungen“, Angew Chem 103,519-41 (1991)

15.   K. Cammann, U. Lemke, A. Rohen, J. Sander, H. Wilken, B. Winter: „Chemical Sensors and Biosensors – Principles and Applications”, Angew Chem Int Ed Engl 30, 516-39 (1991)

16.   B. Winter, K. Cammann: “Formaldehyde Analysis by an Enzymatic FIA-System”, in: F. Scheller, R.D. Schmid (eds.) Biosensors: Fundamentals, Technologies and Applications GBF Monographs 17: pp. 75-78, VCH Verlagsgesellschaft Weinheim (1992)

17.   S. B. Butt, J. Krause, K. Cammann: “Urea Biosensor based on an Ammonia Gas Probe using a NH4+-sensitive PVC-ISE”, in: F. Scheller, R.D. Schmid (eds.) Biosensors: Fundamentals, Technologies and Applications GBF Monographs 17, pp. 79-82, VCH Verlagsgesellschaft Weinheim (1992)

18.   H. Meyer, K. Cammann: “Potentiometric Immunoassay (PIA) – Mixed Potential shift by an Antigen/Antibody Reaction”, in: F. Scheller, R.D. Schmid (eds.) Biosensors: Fundamentals, Technologies and Applications GBF Monographs 17, pp. 83-86, VCH Verlagsgesellschaft Weinheim (1992)

19.   D. Knittel, B. Winter, K. Cammann, E. Schollmeyer: Enzymsensoren und Fließinjektionsanalyse zur Formaldehydbestimmung“, Melliand Textilberichte 2, 195-96 (1992)

20.   U Karst, J. Krause, H. Meyer, M. Wortberg, K. Cammann: „Immunosensoren“, Labor 2000, 62-68 (1992)

21.   K. Jahn, K. Cammann: “Wavelength modulated fluorometry in analysis of Steroid hormones in pharmaceutical products”, “Biosensors 92”, Second World Congress on Biosensors, Proceedings, pp. 236, Elsevier Scientific Publishers Ltd, Oxford (1992)

22.   H. Meyer, K. Cammann: “Potentiometric immuno assay (PIA) – mixed potential modulation by an antigen-antibody reaction”, Biosensors 92”, Second World Congress on Biosensors, Proceedings, pp. 382, Elsevier Scientific Publishers td, Oxford (1992)

23.   B. Riedel, J. Krause, K. Cammann: Integrated optical biosensor using interferometry”, „Biosensors 92“, Second World Congress on Biosensors, Proceedings, pp. 396, Elsevier Scientific Publishers Ltd, Oxford (1992)

24.   U. Karst, K. Cammann: Voltammetric immuno-sensor for the detection of herbicide traces in waters”, “Biosensors 92”, Second World Congress on Biosensors, Proceedings, pp. 516-17, Elsevier Scientific Publishers Ltd, Oxford (1992)

25.   M. Wortberg, J. Krause, K. Cammann: „Development of flow injection analysis for pesticide determination – first studies”, “Biosensors 92”, Second World Congress on Biosensors, Proceedings, pp. 543, Elsevier Scientific Publishers Ltd, Oxford (1992)

26.   M. Wortberg, C. Middendorf, J Krause, K. Cammann: “Development of a flow injection immuno-analysis (FIA) for pesticide determination by means of fluorescence detection”, Proc SPIE-Int Soc Opt Eng 1885, 165-67 (1993)

27.   M. Wortberg, K. Cammann: “Determination of triazine herbicides with time-resolved fluoro-immunoassay using europium(III)-chelates”, Fresenius J Anal Chem 346, 757-60 (1993)

28.   K. Cammann, B. Roß, W. Hasse, C. Dumschat, A. Katerkamp, J. Reinbold, G. Steinhage, B. Gründig, R. Renneberg, N. Buschmann: „Chemical and Biochemical Sensors“, in: Ullmann’s Encyclopedia of Industrial Chemistry, Vol. B 6, pp. 121 -212, VCH Verlagsgesellschaft Weinheim (1994).

29.   N. Conrath, B. Gründig, St. Hüwel, K. Cammann: “A novel enzyme sensor for the determination of inorganic phosphate”, Anal. Chim. Acta, 309 (1 -3), 47-52 (1995)

30.   C. Eggenstein, M. Borchardt, C. Dimischat, B. Gründig, K. Cammann, F. Spener, M. Knoll: „Potentiometrie biosensor in double matrix membrane technology“, Biosensors Bioelectronics, 10,595-600 (1995)

31.   Katerkamp, P. Bolsmann, U. Kunz, M. Niggemann, M. Pellmann, K. Cammann: „The Fiber Optical Surface Plasmon Resonance Sensor, a Promising Transducer for Chemical and Biochemical Sensors”, Sensors ’95, 9.5.-11.5.95, Nürnberg, Germany 349-354 (1995)

32.   U. Rüdel, O. Geschke, K. Cammann: “Entrapment of Enzymes in Electropolymers for Biosensors and Graphite Felt Based Flow-Through Enzyme Reactors”, Electroanalysis 8/12,1135-1139 (1996)

33.   J. Schneider, B. Gründig, R. Renneberg, K. Cammann, M.B. Madaras, R.P. Buck, K.-D. Vorlop: “Hydrogel matrix for three enzyme entrapment in creatine/creatinine amperometric biosensing”, Anal. Chim. Acta 325, 161-167 (1996)

34.   M. Trojanowicz, M.L. Hitchman, K. Cammann: “Conducting Polymers in the Design of Biosensors” in Biosensors: Fundamentals”, University Press, JASI, Rumänien Current Topics in Biophysics 5, ISBN-973-9849-07-85-3, 94-115, 1997;

35.   F. Brosinger, H. Freimuth, M. Lacher, W. Ehrfeld, E. Gedig, A. Katerkamp, F. Spener, K. Cammann: “A label-free affinity sensor with compensation of unspecific protein interaction by a highly sensitive integrated optical Mach-Zehnder interferometer on silicon”, Sensors and Actuators B 44, 350-355, 1997;

36.   K. Cammann, G. Chemnitius, M. Meusel, C. Zaborosch: “Potential and capabilities of biosensors for the assessment of environmental pollutants” in Hock, B., D. Barceló, K. Cammann, P.-D. Hansen, A.P.F. Turner (Eds.): “Biosensors for Environmental Diagnostics” and Hrsg: M. Bahadir, H.-J. Collins, B. Hock Chapter 6: Field experiments: in Teubner-Reihe UMWELT B.G. Teubner Verlag, Stuttgart-Leibzig, ISBN 3-8154-3540-4, 1998;

37.   P. Jülicher, L. Haalck, M. Meusel, K. Cammann und F. Spener: “In situ antigen immobilization for stable organic phase immuno-electrodes”, Anal. Chem. 70, 3362-3367, 1998;

38.   D. Kröger, A. Katerkamp, R. Renneberg, K. Cammann: “Surface investigations on the development of a direct optical immuno-sensor”, Biosensors and Bioelectronics 13, 10, 1141-1147, 1998;

39.   M. Orban, A. Katerkamp, R. Renneberg, F. Spener, K. Cammann: “Kinetic analysis of immunointeractions with covalently immobilized fatty acidbinding protein using a grating coupler sensor”, Journal of Immunological Methods 215, 1-2, 17-26, 1998;

40.   M. Orschel, A. Katerkamp, M. Meusel, K. Cammann: “Evaluation of several methods for the determination of immobilised proteins on gold and silica surfaces”, Colloids and Surfaces B, Biointerfaces 10, 273-279, 1998;

41.   M. Meusel, D. Trau, A. Katerkamp, F. Meier, R. Polzius, K. Cammann: “New ways in bioanalysis -one-way optical sensor chip for environmental analysis-”, Sensors and Actuators B 51, 1-3, 249- 255, 1998;

42.   K. Cammann, G. Chemnitius, M. Meusel, B. Roß: “Automated Field Analyzers for Environmental Pollutants Based on Biosensors” in: D.P. Nicolelis et al. (eds.), Biosensors for Direct Monitoring of Environmental Pollutants in Field, 185-194 Kluwer Academic Academic Publishers'98 Netherlands, Dordrecht NATO-AFI-Serie 2, Nr.38 ISBN 0-7923-4867-2, 1998;